Title Detector for imaging and dosimetry of laser-driven epithermal neutrons by alpha conversion
Contributors
Abstract An epithermal neutron imager based on detecting alpha particles created via boron neutron capture mechanism is discussed. The diagnostic mainly consists of a mm thick Boron Nitride (BN) sheet (as an alpha converter) in contact with a non-borated cellulose nitride film (LR115 type-II) detector. While the BN absorbs the neutrons in the thermal and epithermal ranges, the fast neutrons register insignificantly on the detector due to their low neutron capture and recoil cross-sections. The use of solid-state nuclear track detectors (SSNTD), unlike image plates, micro-channel plates and scintillators, provide safeguard from the x-rays, gamma-rays and electrons. The diagnostic was tested on a proof-of-principle basis, in front of a laser driven source of moderated neutrons, which suggests the potential of using this diagnostic (BN+SSNTD) for dosimetry and imaging applications.
Organisation ISIS , CLF , CLF-HPL , CI , STFC
Keywords imager , epithermal , imaging , neutron
Funding Information
Related Research Object(s):
Licence Information:
Language English (EN)
Type Details URI(s) Local file(s) Year
Journal Article JINST 11, no. 10 (2016): C10008. Is in proceedings of: 4th International Conference on Frontiers in Diagnostics Technologies, Frascati, Italy, 30 Mar 2016 - 1 Apr 2016. doi:10.1088/1748-0221/11/10/C10008 2016