Title Low Power RF Characterisation of the 400 Hz Photoinjector for CLARA
Contributors
Abstract The CLARA High Repetition Rate Photoinjector comprises an S-band dual feed cavity and will operate at a repetition rate of up to 400 Hz and is capable of reaching an electric field strength on the cathode of 120 MV/m. The cavity was brazed after tuning and arrived at Daresbury Laboratory in February 2016. Extensive low power RF testing has been performed including measurements of the quality factors and coupling, pass-band mode frequencies, on axis field and RF repeatability of replacement of cathode plug. The dual feed coupler has been tuned and a Magic Tee type splitter installed. The photoinjector is now installed on the VELA beam line for commissioning and characterisation.
Organisation ASTeC , TECH , CI , STFC
Keywords
Funding Information
Related Research Object(s):
Licence Information:
Language English (EN)
Type Details URI(s) Local file(s) Year
Paper In Conference Proceedings In 8th International Particle Accelerator Conference (IPAC'17), Copenhagen, Denmark, 14-19 May 2017, (2017): 4342-4345. http://accelconf.…/papers/thpik106.pdf 2017