ePubs

The open archive for STFC research publications

Full Record Details

Persistent URL http://purl.org/net/epubs/work/49122
Record Status Checked
Record Id 49122
Title Design of a Phase Space Tomography Module
Contributors
Abstract The Photo Injector Test Facility at DESY in Zeuthen (PITZ) is a European collaboration developing RF photocathode electron guns for light source and linear collider projects. EuroFEL deliverable 1.13 consists of a report describing the design of a phase space tomography diagnostic based on a set of quadrupoles and view screens. In order to measure the beam emittance, four screens with intermediate quadrupole doublets will be used. CCLRC Daresbury Laboratory and DESY-Zeuthen are undertaking this together while the equipment will be installed and tested at PITZ as part of the present facility upgrade. Following simulations of the gun using the ASTRA code at a range of energies, simulations of the electron beam parameters through the matching and tomography sections must be undertaken in order to specify the optimum arrangement of magnets and screens.
Organisation CCLRC , ASTeC , ASTeC-AP , CI
Keywords Physics , Tomography , Diagnostics , EUROFEL
Funding Information
Related Research Object(s):
Licence Information:
Language English (EN)
Type Details URI(s) Local file(s) Year
Report CI Preprints Cockcroft-06-91. 2006. Cockcroft-06-91.pdf 2006