Title Design considerations for phase space tomography diagnostics at the PITZ Facility
Contributors
Abstract A major goal of the Photo Injector Test Facility at DESY in Zeuthen (PITZ) is to build and to optimise high brightness electron sources for SASE FELs where the detailed knowledge of the phase-space distribution of the electron beam is very important. The current upgrade of the PITZ facility includes a diagnostic section suitable for transverse phase space tomography and multiscreen emittance measurements. The designed module should be capable of operation over a range of beam momenta between 15 and 40MV/c. It mainly consists of four observation screens with three FODO cells in between them. An upstream section of a number of quadrupoles is used to match the electron beam Twiss parameters to the tomography section. The design considerations of the tomography section and results from numerical simulations will be presented in this contribution.
Organisation ASTeC , ASTeC-AP , CI , STFC
Keywords Physics , diagnostics , tomography
Funding Information
Related Research Object(s):
Licence Information:
Language English (EN)
Type Details URI(s) Local file(s) Year
Paper In Conference Proceedings In 8th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators (DIPAC 2007), Venice, Italy, 20-23 May 2007, CI Preprints, Cockcroft-07-68 (2007). http://accelconf.…07/papers/tupb23.pdf Cockcroft-07-68.pdf 2007